Thermo Scientific Orion Versa Star Dissolved Oxygen Module, For Versa Star Meters

(No reviews yet) Write a Review
Condition:
New
Shipping:
Calculated at Checkout
Warranty:
1 year replacement Warranty. Details
Returns:
30 Days Money Back Guarantee. Details
$1,258.50

SPW Industrial BBB Business Review
Adding to cart… The item has been added

Brand: Thermo Scientific Orion

Features:

  • VERSA STAR Dissolved Oxygen/RDO/Temperature module easily connects into VERSA STAR meters
  • Dissolved Oxygen/RDO/Temperature module takes the worry out of DO probe compatibility - the meter accepts and automatically recognizes Orion polarographic and RDO optical/luminescence-based probes
  • Compensates automatically for temperature, salinity with manual input and barometric pressure (automatic or manual)
  • Allows for calibration using water-saturated air, air-saturated water, a Winkler titration, or zero point
  • No need to turn off your meter to switch modules -meter automatically recognizes module changes

Thermo Scientific

Details: This Thermo Scientific Orion VERSA STAR Dissolved Oxygen/RDO/Temperature module easily connects into VERSA STAR meters. The Dissolved Oxygen/RDO/Temperature module takes the worry out of DO probe compatibility - the meter accepts and automatically recognizes Orion polarographic and RDO optical/luminescence-based probes. It also compensates automatically for temperature, salinity with manual input and barometric pressure (automatic or manual) and allows for calibration using water-saturated air, air-saturated water, a Winkler titration or zero point. No need to turn off your meter to switch modules -meter automatically recognizes module changes. Temperature Mode Range: -5 degree to 105 degree (23 degree to 221 degree ). Temperature Mode Resolution: 0.1 (0.1). Temperature Mode Relative Accuracy: ±0.1. DO Mode Concentration Range: Polarographic-- 0 to 90mg/L; RDO optical-- 0 to 50mg/L0.01, 0.1. DO Mode Concentration Resolution: 0.01, 0.1. DO Mode Relative Accuracy: Polarographic-- ±0.2mg/L; ±2 percent; RDO optical-- ±0.1mg/L up to 8mg/L, ±0.2mg/L up to 20mg/L, 10 percent of reading beyond; ±2 percent. DO Mode percent Saturation Range: Polarographic-- 0 to 600; RDO optical--0 to 500. DO Mode percent Saturation Resolution: 0.1, 1. DO Mode Salinity Factor: 0 to 45 ppt, manual; automatic if used with conductivity module (sold separately). DO Mode Calibration: Water-saturated air, air-saturated water, manual (Winkler) and zero point. Inputs: 9-pin mini-DIN. Sensor Types: Polarographic or RDO (optical/luminesce-based) DO. Environmental Operating Conditions Relative Humidity: 5 to 85 percent noncondensing. Thermo Scientific Orion #: VSTAR-RD.