Product series
|
FREQROL-A700
|
Type
|
High-performance, high-performance inverter FREQROL-A700 series three-phase 200 V
|
Product no.
|
FR-A 720-22 K
|
Application motor capacity (kW)
|
22 kW
|
Output
|
Rated capacity (kVA)
|
34
|
Rated current (A)
|
90
|
Excessive load current rating
|
60 s 150%, 200% 3 s (anti-limited time characteristics) ambient temperature 50 ° c
|
Voltage
|
3-phase 200 ~ 240V
|
Regeneration control torque
|
The maximum-allowed usage
|
20% torque and continuous
|
Power supply
|
Voltage class
|
Three-phase 200 V class
|
Rated input AC voltage and frequency
|
Three-phase 200 to 220 V 50 Hz, 200-240 V 60 Hz
|
Permissible AC voltage
|
170-242 V 50 Hz and 60 Hz 170-264 V
|
Permissible frequency fluctuation
|
±0. 5%
|
Power capacity (kVA)
|
41
|
Protection structure (JEM 1030)
|
Closed type (IP20)
|
Cooling method
|
Forced air cold
|
Approx. weight (kg)
|
14
|
Control specifications
|
Control method
|
Soft-PWM control and high carrier frequency PWM control can be selected for v/f control, advanced magnetic flux vector control, real censures vector control and vector control (when using optional and FR-A7AP/FR-A7AL)
|
Output frequency range
|
0.2 ~ 400 Hz
|
Frequency setting resolution
|
Analog input
|
0.015 Hz, 0 ~ 60 Hz ( terminals 2, 4: 0-10 V/12 bit ), 0.03 Hz / 0 ~ 60 Hz ( terminals 2, 4: 0 ~ 5 V/11 bit, 0 to 20 mA, 11 bit, Terminal 1:00 ~ ± 10 V/12 bit ), 0.06 Hz / 0 ~ 60 Hz ( Terminal 1:00 ~ ± 5 V/11 bit )
|
Digital input
|
0.01 Hz
|
Frequency accuracy
|
Analog input
|
Maximum output frequency ± 0.2% ( 25 ° c ± 10 ° c )
|
Digital input
|
Less than 0.01% output frequency tuning
|
Voltage and frequency characteristics
|
Base frequency 0-400 Hz setting can be any constant torque and reduces torque pattern, v/f 5-point adjustable rate selectable
|
Starting torque
|
200% 0.3Hz(0.4K ~ 3.7 K ), 0.3Hz(5.5K more than 150% ) (real censures vector control, vector control:)
|
Torque boost
|
Manual torque boost
|
Acceleration and deceleration time setting
|
0 to 3600 s (acceleration and deceleration individually configurable) linear, S-curve acceleration deceleration mode, the backlash against California deceleration can be selected
|
DC braking
|
Adjustable operating frequency (0-120 Hz) and operating time (0-10 s), operating voltage (0 ~ 30%)
|
Stall prevention action level
|
Operating current level setting can be selected (0 ~ 220% variable) the presence or absence
|
Torque limitation levels
|
Torque limit values can be set (0-400% variable)
|