Brand: INTBUYING
Features:
- Electric heating sleeve is adopted for heating, which has the characteristics of large heating area, even heating and fast heating. The maximum surface temperature is 380?äâ
- 50-10000ml standard or non-standard reaction bottles can be heated and stirred.
- 30 bevel control panel is suitable for sitting and standing angles.
- Knob temperature adjustment, LCD display temperature, visual and intuitive, user-friendly design.
- New shell, high temperature resistance, corrosion resistance, and good insulation performance.
Details: Description:
Internal temperature limit protection function. "
Usage:
1. Fix over the blender after poling screw hole, adjust height of cross clamp, place to fasten on the reaction bottle with universal, into the appropriate mixing, insert the power supply to 110 ?ê¿, turn on the switch.
2. Press the ""SPEED"" knob and the ""r/min"" window will display the SPEED. Adjust the ""SPEED"" knob clockwise and adjust it to the appropriate position according to the SPEED display for stirring. After the setting, the ""r/min"" window displays the real-time speed. When the set speed is reached, the speed display window is stable.
3. Press the ""HEAT"" knob to display the temperature in the ""?äâ"" window. Adjust the ""HEAT"" knob clockwise and HEAT it to the required position according to the temperature display. After setting, the ""HEAT"" window displays the measured temperature. During heating, the ""HEAT"" window shows a jump between the measured temperature and the set temperature.
4. Self-setting function: when the self-setting function is started, the heating time is the shortest, the impact temperature is the smallest and the balance is the best when the heating power and solution are irregular in different heating stages. However, the self-setting function should be reset after changing the heating medium or heating condition.
5. Start self-tuning: in the normal measurement control state, press and hold the ""AT"" button for 8 seconds to enter the self-tuning state, and the AT light flashes in the self-tuning state.
6. There is a rubber plug under the mixer, which is used to protect the external thermocouple socket from corrosion and rust and to guide the internal wire. If the plug is removed, the internal probe will be disconnected and the machine will stop working. When using external thermocouple, the plug should be unplugged and stored. Insert the plug of external thermocouple into the socket and lock the nut(051035)